PD132 DC 24V 2s To 5s Automatic Calibration Time Single Channel Vehicle Loop Detector
Product description
PD132 single loop detector is used for wherever vehicles have to be detected , for example for monitoring and
safe-guarding access ways or for counting vehicles. The output signal can be used for controlling door and gate
drive mechanisms, operating barriers, controlling traffic light systems or activating card dispensers in parking lots .
PD132 has two-way output relays , one is unlimited output when the loop is temporarily covered , while the other
is multi-mode that can be set by users .
PRODUCT APPLICATIONS
Automatic Gate
Traffic Light System
Gate Drive Mechanisms
Operating Barriers
Parking Guidance System
Activating Card Dispensers in Parking Lots
PRODUCT TECHNICIAL SPECIFICATIONS
Supply voltage | 230VAC , 115V AC, 12V DC, 24V DC( See the label on the detector) |
Voltage tolerance AC | +10% / -15% |
Voltage tolerance DC | ±15% |
Power Consumption | 4.5VA |
Output relays | 240V/5A |
Operating temperature | -20°C to +65°C |
Storage temperature | -40°C to +85°C |
Frequency range | 20kHz to 170kHz |
Reaction time | 10ms |
Signal holding time | Unlimited / limited when loop is permanently covered 10 minutes |
Sensitivity | Adjustable in 4 increments |
Loop inductance | Total loop plus connection wiring:50μH to 1000μH. Ideal is 100μH to 300μH |
Loop connection wiring | Maximum length 20 meters, twisted at least 20 times per meter |
Size of Housing | 78x40x108 mm (L x W x H) |
Main Features
1) Reset Switch : The reset switch enables the detector to be manually reset during
commissioning and testing . This results in the detector re-tuning the sensing loop and
becoming ready for vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be
energized for 1 Second or 0.5 Seconds ;
3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a
vehicle or when the vehicle leaves the loop ;
4) Sensitivity Boost : This feature sets the undetect level to maximum sensitivity and is used
to prevent loss of detection of high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are available on the switches to allow
flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available to prevent cross-talk
between adjacent loops ;
7) Filter Option : This option is used to provide a delay between detection of the vehicle and
switchiing of the output relay . This relay is normally used to prevent false detection of
small or fast moving objects ;
8) Permanent Presence Option : This feature ensure detection of the vehicle will be maintained
when the vehicle is parked over the loop for extended periods .
PRODUCT INSTALLATION
The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation
location must choose to stay away from the heat source, it around other devices must maintain a distance of at least
10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful
inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install
methods (details as “Loop installation guide”).
Work indicator
Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power,
this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will
not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.
Operation and Indication
While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds,
then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault
is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is
detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the
unit is powered.
Frequency
To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.
Sensitivity
The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce
an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.